The Tracker 2800S can scan and compare up to 40 pins per channel using standard IC clips and Cables. Connections are made through the front panel using standard IDC style connectors. Comparison can take place manually or automatically, allowing you to pick out the signatures’ differences quickly
Tracker Signature Analysis
The Tracker works by applying a current-limited AC signal across two points of a component. The current flow causes a vertical deflection of the CRT trace, while the applied voltage causes a horizontal deflection. Together they form a unique V/I signature that represents the overall health of the device under test. Analyzing the signature can quickly determine whether the component is good, bad, or marginal.
Specifications
Waveform: Sine wave
Test Frequencies: 20 Hz, 50/60 Hz, 200 Hz, 300 Hz and 2k Hz
Open Circuit Voltage: 200mVPK, 3VPK, 5VPK, 10VPK, 15VPK, 20VPK
Source Resistance: 10ohm, 50ohm, 100ohm, 500ohm, 1kohm, 5kohm, 10kohm, 50kohm and 100kohm
Channels:2 (A, B)
Connections:Banana (for Chan. A, Chan. B and Common)
Display Modes: A B ALT
Scan Modes:Manual or Automatic
DC Voltage Generator:Level: 0-+5VDC
Source Resistance: 25Ω
Maximum Current: 200mA
Display:Color TFT LCD with Touch Screen; LED Backlight
Power Requirements
Line Voltage:100/115VAC - 230VAC
Frequency:50/60Hz, 50Hz Weight: 6.0 lb
Warranty: 1 year, limited
Supplied AccessoriesThe Huntron Tracker 2800 comes complete with:
Huntron MP20 MicroProbes
(1 pair)Common test leads
One blue clip lead
"20 and 40 pin DIP clips and cables
Power cord and instruction CDROM